冶 金 动 力 METALLURGICAL POWER 2013年第lO期 总第164期 25 MW汽轮发电机系统优化改造的实践 张 雷 (山东钢铁集团莱芜分公司能源动力厂,山东莱芜271126) 【摘要】分析了莱钢25 MW汽轮发电机在运行中暴露出的设备问题和缺陷,通过对电控油站改造、高低 位油箱设计安装和润滑油冷油器改造等系统优化提升,机组运行更加安全稳定,解决了调速系统部稳定、负荷 波动大、油温超标、电液转换器堵塞和润滑系统不可靠的问题,取得了较好的经济和社会效益。 【关键词】系统波动;油污染;优化;实践 【中图分类号】TM611 【文献标识码】B 【文章编号】1006—6764(2013)10—0034—03 Practice of Optimization Upgrading of 25 MW Steam-turbine Generator Unit Zhang Lei (The Power Plant of Laiwu Steel of Shandong Iron and Steel Group,Laiwu,Shandong 271126,China) 【Abstract]Problems and t'aults emerged during operation of the 25MW steam—turbine generators of Laiwu Steel were analyzed.Through optimization upgrading of the electric—con— trolled oil station,design and installation of upper and lower oil tanks and lubricants cooler, the generating unit operates more safely and stably,solving various problems such as instabil— icy of speed adjustment system,load fluctuations,over—standard oil temperature,clogging of electro-hydraulic converter and unreliable lubrication system and achieving good economic and social benefits. 【Key words]system fluctuation;oil contamination;optimization;practice 1 机组概况 莱钢能源动力厂汽机车间3"25 MW发电机为 提供动力,并将阀位变化反馈到505E控制系统,来 实现调速汽门的开度。 原电控油站(图1)在设计及使用中主要存在以 下缺陷: OF一25—2型发电机,其参数为:发电量2.5万kwh,频 率50Hz;其原动机型号为:c25—3.43/0.981—1 1型单 缸、冲动、单抽凝汽式汽轮机(南京汽轮机厂生产), 额定功率为25 MW,额定转速为3000 r/min。机组 额定工业抽汽量为60 h,于2006年9月安装运 行。 2机组存在的缺陷 3"25 MW汽轮发电机组自2006年9月投产以 来,因原设计缺陷和长周期高负荷运行,逐步暴露出 调速系统不稳定、负荷波动大、油温超标、电液转换 器堵塞、润滑系统不可靠等问题,在2011年2月14 Et厂用电中断时曾发生轴瓦磨损停机检修22天的 事故。 2.1 电控油站缺陷 图1改造前电控油站 2.1.1油泵采用埋人式,联轴器为尼龙材质,磨损产 生的碎屑散入油箱,污染油质。 电控油站负责为机组的调节系统供油,由电控 油泵加压后的润滑油压至4 MPa,向高压和中压油 动机的电液转换器提供压力油,为电磁阀滑阀动作 2.1.2油箱是普通碳钢材质,易被氧化腐蚀,污染油 质,堵塞电液转换器,造成调速系统失灵。