料號 :產品特性 :產品規格 :供應商名稱作業員1:作業員2:作業員3:尺寸3.10H.N.E產品名稱 :高度規 編號:F01-E01-002公差: +0.15/-0.05審核檢測日期:檢測日期:檢測日期:2010/3/252010/3/252010/3/25# 作業員# 試驗330.20量測單位:mm模具號:作業員Sample12345678910TTLSTrial 13.163.153.153.163.143.153.153.163.153.1431.51Trial 23.153.163.143.153.163.143.153.153.163.1431.50Trial 33.153.143.153.153.143.143.153.163.143.1331.45Range0.0100.0200.0100.0100.0200.0100.0000.0100.0200.0100.1200.012SumXA控制試驗TEST上限,上公差
94.4603.149作業員Trial 13.153.143.133.163.153.143.143.153.163.1531.47Trial 23.163.153.143.153.143.153.153.163.143.1531.49Trial 33.163.183.163.173.163.153.163.153.163.1531.60Range0.0100.0400.0300.0200.0200.0100.0200.0100.0200.0000.1800.018SumXB94.5603.152作業員Trial 13.163.153.153.163.143.143.153.143.153.1431.48Trial 23.153.163.143.153.163.143.153.153.163.1431.50Trial 33.153.143.133.163.153.143.143.153.163.1531.47Range0.0100.0200.0200.0100.0200.0000.0100.0100.0100.0100.1200.012SumXC94.4503.148X min3.1483.1522.57x0.014=0.036X max如果任何一個范圍超過此限制,那麼此測量值或讀數都應評審、重復、糾正、適當地刪除,並且要計算出新的平均值和范圍。
X diff0.004If any individual range exceeds this limit, the measurement or reading should be reviewed, repeated, corrected, or discarded asappropriate, and new averages and ranges should becomputed因素Factors# Trials23# Oprs23K14.563.05K23.652.70D43.27n=# parts零件數量, t=#2.57trials試驗次數測量系統
MEASUREMENT
SYSTEM / 量具GAUGE/ 能力CAPABILITY
重復性
Repeatability% 公差Tolerance
設備變差
Equipment
Variation(再現性\"Repeatability\") =K1R =
3.050x0.014=0.0427021.35%評價人變差OperatorVariation(再現性\"Reproducibility\") =
(K2*Xdiff)2 -(EV)2/nxt
再現性
Reproducibility% 公差Tolerance0.006103.05%總Total
總的“重復性”和“再現性”變差Total\"repeatability\" and\"reproducibility\"Variation(R&R)=Notes:合格: 0 2009/07/02 因篇幅问题不能全部显示,请点此查看更多更全内容