橡套电缆护套厚度表60245IEC66(YCW)450/750V橡套软电缆 YC规格1*1.51*2.51*41*61*101*161*251*351*501*701*951*1201*1501*1851*2401*3001*400标称最薄最厚YC YCW450/750V橡套软电缆规格4*1.04*1.54*2.54*44*64*104*164*254*354*504*704*954*1204*1505*1.05*1.55*2.55*45*65*105*165*25标称最薄最厚规格2*1.02*1.52*2.52*42*62*102*162*253*1.03*1.53*2.53*43*63*103*163*253*353*503*703*95标称最薄最厚规格3*2.5+1*1.53*4+1*2.53*6+1*43*10+1*63*16+1*63*25+1*103*35+1*103*50+1*163*70+1*253*95+1*353*120+1*353*150+1*502*352*502*702*953*1203*150标称最薄最厚mm1.401.401.501.601.801.902.002.202.402.602.803.003.203.403.503.603.80mm1.191.191.281.361.531.621.701.872.042.212.382.552.722.892.983.063.23mm1.541.541.651.761.982.092.202.422.642.863.083.303.523.743.853.964.18mm1.301.501.701.802.003.103.303.601.401.601.801.902.103.303.503.804.104.504.805.30mm1.111.281.451.531.702.642.813.061.191.361.531.621.792.812.983.233.493.834.084.51mm1.431.651.871.982.203.413.633.961.541.761.982.092.313.633.854.184.514.955.285.83mm1.501.701.902.002.303.403.604.104.404.805.205.906.006.501.601.802.002.202.503.603.904.40mm1.281.451.621.701.962.893.063.493.744.084.425.025.105.531.361.531.701.872.133.063.323.74mm1.651.872.092.202.533.743.964.514.845.285.726.496.607.151.761.982.202.422.753.964.294.84mm2.002.002.203.003.504.004.005.005.005.005.005.003.904.304.605.005.606.00mm1.701.701.872.552.983.403.404.254.254.254.254.253.323.663.914.254.765.10mm2.202.202.423.303.854.404.405.505.505.505.505.504.294.735.065.506.166.60检验依据:JB8735.2-1998,耐压试验2.5KV/5minYCW检验依据:GB/T5013.4-2008,耐压试验2.5KV/5min ;YC检验依据:JB8735.2-1998,耐压试验2.5KV/5min20℃绝缘电阻最小值:主线芯50mm2以下的,不小于50MΩ.Km;主线芯50mm2及以上的,不小于30MΩ.Km。60245IEC53(YZ)、60245IEC(YZW)、YZF300/500V橡套软电缆规格2*0.752*1.02*1.52*2.53*0.753*1.03*1.53*2.54*0.754*1.04*1.54*2.55*0.755*1.05*1.55*2.5标称最薄最厚YZ、YZW、YZF300/500V橡套软电缆规格标称最薄最厚60245IEC81(YH)、60245IEC82(YHF)电焊机电缆电缆外径最厚标称最大规格1*101*161*251*351*501*701*95标称最薄mm0.800.901.001.100.900.901.001.100.900.901.101.201.001.001.101.30mm0.680.770.850.940.770.770.850.940.770.770.941.020.850.850.941.11mm0.880.991.101.210.990.991.101.210.990.991.211.321.101.101.211.43mmmmmmmm1.802.002.002.002.202.402.60mmmmmmmm9.1011.0012.7014.2016.5019.2021.402*41.201.021.322*61.301.111.433*41.201.021.323*61.301.111.434*41.301.111.434*61.401.191.545*41.401.191.545*61.601.361.766*0.751.000.851.106*1.01.100.941.216*1.51.201.021.326*2.51.401.191.546*4.01.501.281.656*6.01.701.451.873*1.5+1*11.100.941.213*2.5+1*1.51.201.021.323*4+1*2.51.301.111.43YZF检验依据:Q/JL101.019-200860245IEC(YZW)检验依据:GB/T5013.4-20083*6+1*41.401.191.5460245IEC53(YZ)检验依据:GB/T5013.4-2008,YZF检验依据:Q/JL101.019-2008耐压试验2.0KV/5min YZ、YZW检验依据:JB8735.2-1998耐压试验2.0KV/5min 20℃绝缘电阻最小值:主线芯35mm2及以下的,不小于50MΩ.Km 主线芯50mm2及以上的,不小于30MΩ.Km1.531.988.601.702.2010.301.702.2011.801.702.2013.101.872.4215.202.042.6417.902.212.8620.00检验依据GB5013.6-2008耐压试验1KV/5min MYQ 0.3/0.5KV煤矿用移动软电缆标称mm1.501.50最薄mm1.281.281.281.281.281.281.281.281.701.281.701.701.702.132.13最厚mm1.651.651.651.651.651.651.651.652.201.652.202.202.202.752.75规格2*12*1.52*2.53*13*1.53*2.54*14*1.54*2.57*17*1.57*2.512*112*1.512*2.51.501.501.501.501.501.502.001.502.002.002.002.502.50MZ、MZP0.3/0.5KV煤矿用电钻电缆型号规格标称最薄最厚MY0.38/0.66KV煤矿用橡套软电缆规格1*41*61*101*161*251*351*501*701*951*1201*1501*1851*2401*3001*4003*4+1*43*6+1*63*10+1*103*16+1*103*25+1*163*35+1*163*50+1*163*70+1*253*95+1*253*120+1*353*150+1*50标称最薄最厚型号规格MYP0.66/1.14KV及以下煤矿用橡套软电缆标称最薄最厚mmmmmm3.853.853.853.853.853.853.853.85mm1.501.601.801.902.002.202.402.602.803.003.203.403.503.603.803.503.504.004.004.504.505.005.005.505.506.00mm1.281.361.531.621.701.872.042.212.382.552.722.892.983.063.232.982.983.403.403.833.834.254.254.684.685.10mm1.651.761.982.092.202.422.642.863.083.303.523.743.853.964.183.853.854.404.404.954.955.505.506.056.056.60mmmmmm3*2.5+1*2.53.502.983*4+1*43.502.98MZ3*2.5+1*2.5+1*2.53.502.983*4+1*4+1*43.502.983*2.5+1*2.53.502.983*4+1*43.502.98MZP3*2.5+1*2.5+1*2.53.502.983*4+1*4+1*43.502.98检验依据:MT818.8-2009,耐压试验:2.0KV/5min 20℃绝缘电阻最小值: 160MΩ.KmMYP3.6/6KV煤矿用橡套软电缆规格标称最薄最厚mmmmmm3*16+1*165.504.686.053*25+1*165.504.686.053*35+1*165.504.686.053*50+1*165.504.686.053*70+1*256.005.106.603*95+1*356.005.106.603*120+1*356.005.106.603*150+1*506.005.106.60检验依据:MT818.7-200912.5KV/5min 20℃绝缘电阻最小值: 160MΩ.Km3*4+1*43.502.983.853*6+1*63.502.983.853*10+1*104.003.404.40MYP3*16+1*104.003.404.403*25+1*164.503.834.953*35+1*164.503.834.953*50+1*165.004.255.503*70+1*255.004.255.50038/0.66KV3*95+1*255.504.686.053*120+1*355.504.686.053*150+1*506.005.106.603*10+1*104.503.834.953*16+1*104.503.834.953*25+1*165.004.255.50MYP3*35+1*165.004.255.503*50+1*165.504.686.053*70+1*255.504.686.053*95+1*256.005.106.600.66/1.14KV3*120+1*356.005.106.603*150+1*506.005.106.60MY、MYP.38/0.66KV、MYP0.66/1.14KV检验依据:MT818.5-2009MY20℃绝缘电阻最小值100MΩ.Km备注MYP20℃绝缘电阻最小值160MΩ.Km0.38/0.66KV耐压试验:3.0KV/5min0.66/1.14KV耐压试验:3.7KV/5min